Image is illustrative
|
Ultrasonic Sensor UC500-30GM-IUR2-V15, Sn 30...500mm, output 4...20mA/0...10V, RS232, LED, -25..70°C, ss1.4305, PBT, M12 5pin, 10..30VDC, IP65, Pepperl+Fuchs Code:
104092
Price (indicative)
€278.60
/pc
(€339.89 /pc with VAT)
Manufacturer
:
Availability:
21 days
|
Weight:
0.1785 kg/pc
|
Volume:
0.0002 m3/pc
|
|
|
|
|
Ultrasonic Sensor UC500-30GM-IUR2-V15, Sn 30...500mm, output 4...20mA/0...10V, RS232, LED, -25..70°C, ss1.4305?PBT, M12 5pin, 10..30VDC, IP65, Pepperl+FuchsUltrasonic sensor UC500-30GM-IUR2-V15
- Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 3000
- Analog current and voltage output
- Synchronization options
- Adjustable acoustic power and sensitivity
- Temperature compensation
Datasheet excerpt: Technical data of UC500-30GM-IUR2-V15
Product Description |
Single head system |
General specifications |
Sensing range | 30 ... 500 mm |
Adjustment range | 50 ... 500 mm |
Dead band | 0 ... 30 mm |
Standard target plate | 100 mm x 100 mm |
Transducer frequency | approx. 380 kHz |
Response delay | 21 ms minimum 63 ms factory setting |
Indicators/operating means |
LED green | solid: Power-on flashing: Standby mode or program function object detected |
LED yellow 1 | solid: object in evaluation range flashing: program function |
LED yellow 2 | solid: object in detection range flashing: program function |
LED red | solid: temperature/program plug not connected flashing: fault or program function object not detected |
Temperature/TEACH-IN connector | Temperature compensation , Evaluation range programming , output function setting |
Electrical specifications |
Operating voltage | 10 ... 30 V DC , ripple 10 %SS |
Power consumption | ≤ 900 mW |
Interface |
Interface type | RS 232, 9600 Bit/s , no parity, 8 data bits, 1 stop bit |
Input/Output |
Synchronization | bi-directional 0 level -UB...+1 V 1 level: +4 V...+UB input impedance: > 12 KOhm synchronization pulse: ≥ 100 µs, synchronization interpulse period: ≥ 2 ms |
Synchronization frequency | |
| Common mode operation | max. 95 Hz |
| Multiplex operation | ≤ 95 Hz / n , n = number of sensors , n ≤ 5
|
Output |
Output type | 1 current output 4 ... 20 mA 1 voltage output 0 ... 10 V |
Resolution | evaluation range [mm]/4000, but ≥ 0.05 mm |
Deviation of the characteristic curve | ≤ 0.2 % of full-scale value |
Repeat accuracy | ≤ 0.1 % of full-scale value |
Load impedance | current output: ≤ 500 Ohm Voltage output: ≥ 1000 Ohm |
Temperature influence | ≤ 2 % from full-scale value (with temperature compensation) ≤ 0.2 %/K (without temperature compensation) |
Approvals and certificates |
UL approval | cULus Listed, General Purpose |
CSA approval | cCSAus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications |
Connection type | Connector M12 x 1 , 5-pin |
Degree of protection | IP65 |
Material | |
| Housing | stainless steel (1.4305 / AISI 303) PBT plastic parts |
| Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam |
Mass | 170 g |
|
|
|
|
|