Image is illustrative
|
Redundant Adapter Module ControlLogix, 2-ch., Ethernet/IP/ 10/100MBPS, 18..30VDC, TS35, Allen-Bradley Code:
1715-AENTR
Price (indicative)
€2,724.59
/pc
(€3,324.00 /pc with VAT)
Manufacturer
:
Availability:
28 days
|
Weight:
0.626 kg/pc
|
Volume:
0.004 m3/pc
|
|
|
|
|
Redundant Adapter Module ControlLogix, 2-ch., Ethernet/IP/ 10/100MBPS, 18..30VDC, TS35, Allen-Bradley
DESCRIPTIONS
ControlLogix® Redundant Adapter Module, Number Of Channels: 2, Voltage Rating: Backplane: 18 - 30 VDC, Isolation: 50 V (Continuous), Basic Insulation Type, Ethernet Ports To Backplane And Ethernet Ports To DC Power Ports, No Isolation Between Individual Ethernet Ports, No Isolation Between DC Power Ports, Type Tested At 500 VAC For 60 SEC, Enclosure: Open Type, Rfi Suppression: Radiated: 20 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 1000 MHZ, 10 V/M With 1 KHZ Sine-Wave 80% AM From 1000 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ, Display: Module Health And Status, Memory: Boot Flash: 512 KB, SRAM: 512 KB, Bulk Flash: 64 MB, SDRAM: 32 MB, Communication: Ethernet/IP, 10/100 MBPS, Mounting: DIN Rail, Length: 1-5/8 IN, Width: 4-5/8 IN, Height: 6-1/2 IN, Temperature Rating: -13 To 158 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 2 G, Shock Operating - Din Rail Mount: 25 G, Panel Mount: 30 G, Shock Non-Operating - Installed: 30 G, Uninstalled: 50 G, Power Dissipation: 8 W, Surge Transient Immunity: Plus/Minus 1 KV Line-Line (DM) and Plus/Minus 2 KV Line-Earth (CM) On Power/Shielded Ethernet Ports, Standard/Approvals: C/US UL listed, CE certified, C-Tick certified, GOST_R certified, KCC certified, ROSTECHNADZOR
SPECIFICATIONS
-
Item Name: Redundant Adapter Module
-
Sub Brand: ControlLogix®
-
Number Of Channels: 2
-
Voltage Rating: Backplane: 18 - 30 VDC
-
Isolation: 50 V (Continuous), Basic Insulation Type, Ethernet Ports To Backplane And Ethernet Ports To DC Power Ports, No Isolation Between Individual Ethernet Ports, No Isolation Between DC Power Ports, Type Tested At 500 VAC For 60 SEC
-
Enclosure: Open Type
-
Rfi Suppression: Radiated: 20 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 1000 MHZ, 10 V/M With 1 KHZ Sine-Wave 80% AM From 1000 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ
-
Display: Module Health And Status
-
Memory: Boot Flash: 512 KB, SRAM: 512 KB, Bulk Flash: 64 MB, SDRAM: 32 MB
-
Communication: Ethernet/IP, 10/100 MBPS
-
Mounting: DIN Rail
-
Length: 1-5/8 IN
-
Width: 4-5/8 IN
-
Height: 6-1/2 IN
-
Temperature Rating: -13 To 158 DEG F
-
Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 2 G, Shock Operating - Din Rail Mount: 25 G, Panel Mount: 30 G, Shock Non-Operating - Installed: 30 G, Uninstalled: 50 G
-
Power Dissipation: 8 W
-
Surge Transient Immunity: Plus/Minus 1 KV Line-Line (DM) and Plus/Minus 2 KV Line-Earth (CM) On Power/Shielded Ethernet Ports
FEATURES
A 1715 Redundant I/O system is comprised of a pair of partnered Ethernet adapter modules that communicate to ControlLogix controllers via an EtherNet/IP network, and digital and analog I/O modules that are configurable in simplex and duplex modes. The backplane for the system is assembled by connecting a 2- slot adapter base unit with up to eight 3-slot I/O base units, for a total of 24 available I/O modules per system. The base units, via termination assemblies, provide the interconnections for power, adapter, and I/O data. The redundant, partnered adapter modules monitor inputs/outputs and diagnostics for the I/O in the remote chassis. Should a fault occur in one of the redundant adapters, an IP address switchover occurs and I/O monitoring and communication to the ControlLogix System continues without interruption. This switchover is completely transparent to the user. - Standards: C/US UL listed, CE certified, C-Tick certified, GOST_R certified, KCC certified, ROSTECHNADZOR
|
|