Digital DC Input Module ControlLogix, 16-ch., 90..146VDC, 250mA, Allen-Bradley
DESCRIPTIONS
-
ControlLogix® Digital DC Input Module, Number Of Channels: 16 (Individually Isolated), Input: Off-State Voltage: 20V DC (Maximum), Off-State Current: 0.8 MA (Maximum), On-State Current: 1 MA At 90 VDC (Minimum), 3 MA At 146 VDC (Maximum), On-State Voltage: 90 - 146 VDC, 90 - 146 VDC At 50 DEG, 12 Channels ON, 90 - 132 VDC At 55 DEG C, 14 Channels ON, 90 - 125 VDC At 60 DEG C, 16 Channels ON, 90 - 146 VDC At 30 DEGC, 16 Channels ON, Voltage Rating: 90 - 146 VDC, Current Rating: Drawn: 125 MA At 5.1V, 3 MA At 24V, Inrush: 250 MA, Isolation: 250 V (Continuous), Basic Insulation Type, Inputs-To-Backplane And Input-To-Input Routine Tested At 1350 VAC For 2 SEC, Power Rating: Backplane: 0.71 W, Enclosure: Open Type, Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10V rms With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ, Mounting: Chassis, Temperature Rating: 0 - 60 DEG C, Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration: 2 G At 10 - 500 HZ, Shock: 30 G Operating, 50 G Non-Operating, Response Time: Input Delay Time: Off To On- Hardware Delay: 2 MS Maximum + Filter Time, User-Selectable Filter Time: 1 Or 2 MS, On To Off - Hardware Delay: 6 MS Maximum + Filter Time, User-Selectable Filter Time: 0, 1, 2, 9 Or 18 MS, Cyclic Update: 200 MIC-SEC - 750 MS, Power Dissipation: 5 W At 60 DEG C, Output Type: Current Sinking/Source, Impedance: 48.67 KOHM At 146 VDC, Surge Transient Immunity: Plus/Minus 1 KV line-line (DM) and Plus/Minus 2 KV line-earth (CM) on signal ports, Standard/Approvals: US/UL listed, CSA, C-tick, FM, CE-EMC, CE-LVD, CSA, CSA_HAZ, C-tick, FM-US_HAZ, GOST_R, marine-ABS, marine-BVS, marine-DNV, marine-GL, marine-LR, ROSTECHNADZOR
SPECIFICATIONS
-
-
Item Name: Digital DC Input Module
-
Sub Brand: ControlLogix®
-
Number Of Channels: 16 (Individually Isolated)
-
Input: Off-State Voltage: 20V DC (Maximum), Off-State Current: 0.8 MA (Maximum), On-State Current: 1 MA At 90 VDC (Minimum), 3 MA At 146 VDC (Maximum), On-State Voltage: 90 - 146 VDC, 90 - 146 VDC At 50 DEG, 12 Channels ON, 90 - 132 VDC At 55 DEG C, 14 Channels ON, 90 - 125 VDC At 60 DEG C, 16 Channels ON, 90 - 146 VDC At 30 DEGC, 16 Channels ON
-
Voltage Rating: 90 - 146 VDC
-
Current Rating: Drawn: 125 MA At 5.1V, 3 MA At 24V, Inrush: 250 MA
-
Isolation: 250 V (Continuous), Basic Insulation Type, Inputs-To-Backplane And Input-To-Input Routine Tested At 1350 VAC For 2 SEC
-
Power Rating: Backplane: 0.71 W
-
Enclosure: Open Type
-
Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10V rms With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ
-
Mounting: Chassis
-
Temperature Rating: 0 - 60 DEG C
-
Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration: 2 G At 10 - 500 HZ, Shock: 30 G Operating, 50 G Non-Operating
-
Response Time: Input Delay Time: Off To On- Hardware Delay: 2 MS Maximum + Filter Time, User-Selectable Filter Time: 1 Or 2 MS, On To Off - Hardware Delay: 6 MS Maximum + Filter Time, User-Selectable Filter Time: 0, 1, 2, 9 Or 18 MS, Cyclic Update: 200 MIC-SEC - 750 MS
-
Power Dissipation: 5 W At 60 DEG C
-
Output Type: Current Sinking/Source
-
Surge Transient Immunity: Plus/Minus 1 KV line-line (DM) and Plus/Minus 2 KV line-earth (CM) on signal ports
-
Impedance: 48.67 KOHM At 146 VDC
FEATURES
-
- Per Point Isolation
- I/O Ready Cable
- 40 Conductor
- Standards: US/UL listed, CSA, C-tick, FM, CE-EMC, CE-LVD, CSA, CSA_HAZ, C-tick, FM-US_HAZ, GOST_R, marine-ABS, marine-BVS, marine-DNV, marine-GL, marine-LR, ROSTECHNADZOR
|