Image is illustrative
|
Programmable Controller MicroLogix1200, 24-ch., DF1, DH485, Modbus RTU, ASCII, RS232C, 120VAC 250mA inrush, TS35, panel mount, Allen-Bradley Code:
1762-L24AWA
Price (indicative)
€290.80
/pc
(€354.78 /pc with VAT)
Manufacturer
:
Availability:
21 days
|
Weight:
0.667 kg/pc
|
Volume:
0.0019 m3/pc
|
|
|
|
|
Programmable Controller MicroLogix1200, 24-ch., DF1 ˄DH485 ˄Modbus RTU ˄ASCII ˄RS232C, 120VAC 250mA inrush, TS35 ˄panel mount, Allen-Bradley
DESCRIPTIONS
-
MicroLogix™ 1200 Programmable Controller, Number Of Channels: 24 (14 Input, 10 Output), Input: 120 VAC, Input Voltage Range: 85 - 265 VAC At 47 - 63 HZ, Input Voltage - Nominal: 100/120 VAC, 200/240 VAC, On-State Voltage Range: 79 - 132 VAC, Off-State Voltage Range: 0 - 20 VAC, On-State Current: 5 MA At 79 VAC, Off-State Leakage Current: 2.5 MA, Output: Power Supply Output: 400 MA At 5 VDC, 350 MA At 24 VDC, Continuous Output Current: 8 A/Common, 30 A Total At 150 VAC, 20 A Total At 240 VAC, Relay, Current Rating: Inrush Current: 250 MA, Power Supply Maximum Inrush: 25 A For 8 MS At 120 VAC, 40 A For 4 MS At 240 VAC, Enclosure: IP20, Memory: 6 KB, Communication: DF1, DH-485, Modbus RTU, ASCII, RS-232C, Mounting: DIN Rail, Panel, Length: 4.33 IN, Width: 3.43 IN, Height: 3.54 IN, Temperature Rating: 32 - 131 DEG F, Environmental Conditions: Operating Humidity: 5 - 95% Non-Condensing, Vibration Operating: 10 - 500 HZ, 5 G, 0.03 IN Max Peak-To-Peak, Relay Operation: 1.5 G, Shock - Operating Shock: 30 G, Shock, Relay Operation: 7 G, Non-Operating Shock: 50 G Panel Mounted, 40 G DIN Rail Mounted, Response Time: Input Signal Delay (On): 2 - 20 MS, Power Supply: Apparent Input Power: 68 VA, Real Input Power: 29 W, Standard/Approvals: C/US UL listed, UL 508, CSA C22.2, file number 142, Class I, Div. 2, Groups A, B, D, B, C-TICK, GOST_R, KCC, MARINE-ABS, MARINE-BVS, MARINE-DNV, MARINE-GL, MARINE-KRS, MARINE-LR, ROSTECHNADZOR
SPECIFICATIONS
-
-
Item Name: Programmable Controller
-
Sub Brand: MicroLogix™ 1200
-
Number Of Channels: 24 (14 Input, 10 Output)
-
Input: 120 VAC, Input Voltage Range: 85 - 265 VAC At 47 - 63 HZ, Input Voltage - Nominal: 100/120 VAC, 200/240 VAC, On-State Voltage Range: 79 - 132 VAC, Off-State Voltage Range: 0 - 20 VAC, On-State Current: 5 MA At 79 VAC, Off-State Leakage Current: 2.5 MA
-
Output: Power Supply Output: 400 MA At 5 VDC, 350 MA At 24 VDC, Continuous Output Current: 8 A/Common, 30 A Total At 150 VAC, 20 A Total At 240 VAC, Relay
-
Current Rating: Inrush Current: 250 MA, Power Supply Maximum Inrush: 25 A For 8 MS At 120 VAC, 40 A For 4 MS At 240 VAC
-
Enclosure: IP20
-
Memory: 6 KB
-
Communication: DF1, DH-485, Modbus RTU, ASCII, RS-232C
-
Mounting: DIN Rail, Panel
-
Length: 4.33 IN
-
Width: 3.43 IN
-
Height: 3.54 IN
-
Temperature Rating: 32 - 131 DEG F
-
Environmental Conditions: Operating Humidity: 5 - 95% Non-Condensing, Vibration Operating: 10 - 500 HZ, 5 G, 0.03 IN Max Peak-To-Peak, Relay Operation: 1.5 G, Shock - Operating Shock: 30 G, Shock, Relay Operation: 7 G, Non-Operating Shock: 50 G Panel Mounted, 40 G DIN Rail Mounted
-
Response Time: Input Signal Delay (On): 2 - 20 MS
-
Power Supply: Apparent Input Power: 68 VA, Real Input Power: 29 W
FEATURES
-
The MicroLogix 1200/1762 system provides functionality between the MicroLogix 1000/1761 and MicroLogix 1500/1764 systems, using the proven MicroLogix and SLC family architecture. The 6K-word memory provides for a maximum program of 4K words and maximum data of 2K words with 100% data retention. An optional memory module provides program and data backup with program upload and download capability. The optional real-time clock enables time scheduling of control activities. The flash upgradeable operating system lets you upgrade system software without replacing hardware. - Small footprint - it is designed to optimize panel space
- Flexibility - 24 or 40 built-in I/O, the inputs are either 24 VDC (sink or source) or 120 VAC, outputs are relay contact or FET, add up to 96 I/O in up to 6 digital and/or analog I/O modules
- Wide range of communication and high functionality
- Four latching or pulse-catch inputs - latching inputs let the controller capture and hold very brief (microsecond) signals for input processing
- 20 KHZ high-speed counter - the built-in independent high-speed counter uses 32-bit integers for extended range, features 8 modes of operation, and supports direct control of outputs independent of program scan
- Programmable limit switch function - the programmable limit switch function allows to configure the high-speed counter to operate as a programmable limit switch or rotary cam switch
- Trim potentiometers - two built-in 3/4-turn analog trim potentiometers with a digital output (range from 0 to 250) allow quick and easy adjustments of timers, counters, setpoints, and more
- Program data security - data file download protection lets a program be reloaded into the controller without overwriting protected data
- Floating point data file
- Memory, real-time clock, or memory/real-time clock modules - memory backup provides protection and transportability for programs and data, the real-time clock easily solve time/date scheduling applications, and can be synchronized with an external source via a program instruction
- Four interrupt inputs - interrupt inputs let the controller scan a specific program file (subroutine) when an input condition is detected from a sensor or field device
- Standards: C/US UL listed, UL 508, CSA C22.2, file number 142, Class I, Div. 2, Groups A, B, D, B, C-TICK, GOST_R, KCC, MARINE-ABS, MARINE-BVS, MARINE-DNV, MARINE-GL, MARINE-KRS, MARINE-LR, ROSTECHNADZOR
|
|
|
|