Image is illustrative
|
Specialty Input Module Flex I/O, 4-ch., high resolution frequency, 220mA 19.2..31.2VDC, Allen-Bradley Code:
1794-IJ2
Price (indicative)
€497.10
/pc
(€606.46 /pc with VAT)
Manufacturer
:
Availability:
21 days
|
Weight:
0.145 kg/pc
|
Volume:
0.0004 m3/pc
|
|
|
|
|
Specialty Input Module Flex I/O, 4-ch., high resolution frequency, 220mA 19.2..31.2VDC, Allen-Bradley
DESCRIPTIONS
-
Flex™ I/O Specialty Input Module, Type: High Resolution Frequency, Number Of Channels: 4 (2 Input, 2 Output Isolated), Input: On-Stage Voltage: 10 V, On-State Voltage: 50 MVAC, 28 VAC Peak - Extended Magnetic Pickup: 500 MVAC, 28 VAC Peak - Magnetic Pickup: Less Than 3 V - Vortex Flowmeter Low Range, Greater Than 6 V - Vortex Flowmeter High Range, 24 VDC IEC Plus 1 Proximity Or Encoder Input, 24 VDC Contact Switch Input, On-State Voltage: Limited To Isolated 24 VDC Power Supply (Maximum), On-State Current: 10 MA, Off-State Current: 1.5 MA Into 24 VDC IEC Plus Terminal, Off-State Voltage: 5 VDC On 24 VDC IEC Plus 1 Terminal, Output: Output Voltage: 31.2 VDC, Off-State Voltage: 31.2 VDC, On-State Current: 1 MA Per Output Minimum, 1 A Per Channel Sourced Out Of Module Maximum, Off-State Leakage: Less Than 300 MICRO-A At 31.2 VDC Maximum, On-State Voltage Drop: 0.9 VDC At 1 A, Voltage Rating: External Power: 19.2 - 31.2 VDC, Isolated DC Power Voltage Range: 21.6 - 26.4 VDC, Current Rating: External DC Power Supply Current: 220 MA At 19.2 VDC, 180 MA At 24 VDC, 140 MA At 31.2 VDC, Isolated DC Power Supply Current: 0 - 60 MA Maximum At 24 VDC, Isolation: 50 V (Continuous), Basic Insulation Type, Tested At 1365 VAC For 60 SEC, Between Field Side And System And Individual Channels, Control: Output Control: Outputs Individually Assignable To: Frequency, % Full Scale Or Acceleration Alarm, Enclosure: Open Type, Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 Hz 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 Hz 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ On Shielded Signal Ports, Mounting: DIN Rail, Panel, Length: 3.7 IN, Width: 2.7 IN, Height: 3.7 IN, Temperature Rating: -4 To 158 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration: 5 G At 10 - 500 HZ, Shock - Operating: 30 G, Non-Operating: 50 G, Response Time: Input Pulse Width: 20 MIC-SEC, Output Switching Time - Turn On: Less Than 0.5 MS, Turn Off: Less Than 1 MS, Processing Time: Less Than 4 MS, Power Dissipation: 4.6 W At 31.2 VDC, Impedance: Frequency Input Impedance: Greater Than 5 KOHM For 50 MIL-V Extended Magnetic Pickup, Greater Than 5 KOHM For 500 MIL-V Magnetic Pickup, Greater Than10 KOHM For 3 V Vortex Flowmeter Low Range, Greater Than 10 KOHM For 6 V Vortex Flowmeter High Range, Greater Than 2.5 KOHM For 24 VDC IEC+1 Proximity Or Encoder Input, Greater Than 2.5 KOHM For 24 VDC Contact Switch Input, Gate Input Impedance: Greater Than 5 KOHM For 50 MIL-V Extended Magnetic Pickup, Greater Than 5 KOHM For 500 MIL-V Magnetic Pickup, Greater Than 2.5 KOHM For 24 VDC IEC+1 Proximity Or Encoder Input, Greater Than 2.5 KOHM For 24 VDC Contact Switch Input, Indicator: 1 Green/Red Power/Status Indicator, 4 Yellow Status Indicators (Freq 0, 1, Gate 0, 1), 4 Red Wire-Off Indicators (Freq 0, 1, Gate 0, 1), 2 Yellow Status Indicators (Out 0, Out 1) - Logic Side
SPECIFICATIONS
-
-
Item Name: Specialty Input Module
-
Type: High Resolution Frequency
-
Sub Brand: Flex™ I/O
-
Number Of Channels: 4 (2 Input, 2 Output Isolated)
-
Input: On-Stage Voltage: 10 V, On-State Voltage: 50 MVAC, 28 VAC Peak - Extended Magnetic Pickup: 500 MVAC, 28 VAC Peak - Magnetic Pickup: Less Than 3 V - Vortex Flowmeter Low Range, Greater Than 6 V - Vortex Flowmeter High Range, 24 VDC IEC Plus 1 Proximity Or Encoder Input, 24 VDC Contact Switch Input, On-State Voltage: Limited To Isolated 24 VDC Power Supply (Maximum), On-State Current: 10 MA, Off-State Current: 1.5 MA Into 24 VDC IEC Plus Terminal, Off-State Voltage: 5 VDC On 24 VDC IEC Plus 1 Terminal
-
Output: Output Voltage: 31.2 VDC, Off-State Voltage: 31.2 VDC, On-State Current: 1 MA Per Output Minimum, 1 A Per Channel Sourced Out Of Module Maximum, Off-State Leakage: Less Than 300 MICRO-A At 31.2 VDC Maximum, On-State Voltage Drop: 0.9 VDC At 1 A
-
Voltage Rating: External Power: 19.2 - 31.2 VDC, Isolated DC Power Voltage Range: 21.6 - 26.4 VDC
-
Current Rating: External DC Power Supply Current: 220 MA At 19.2 VDC, 180 MA At 24 VDC, 140 MA At 31.2 VDC, Isolated DC Power Supply Current: 0 - 60 MA Maximum At 24 VDC
-
Isolation: 50 V (Continuous), Basic Insulation Type, Tested At 1365 VAC For 60 SEC, Between Field Side And System And Individual Channels
-
Control: Output Control: Outputs Individually Assignable To: Frequency, % Full Scale Or Acceleration Alarm
-
Enclosure: Open Type
-
Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 Hz 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 Hz 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ On Shielded Signal Ports
-
Mounting: DIN Rail, Panel
-
Length: 3.7 IN
-
Width: 2.7 IN
-
Height: 3.7 IN
-
Temperature Rating: -4 To 158 DEG F
-
Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration: 5 G At 10 - 500 HZ, Shock - Operating: 30 G, Non-Operating: 50 G
-
Response Time: Input Pulse Width: 20 MIC-SEC, Output Switching Time - Turn On: Less Than 0.5 MS, Turn Off: Less Than 1 MS, Processing Time: Less Than 4 MS
-
Power Dissipation: 4.6 W At 31.2 VDC
-
Indicator: 1 Green/Red Power/Status Indicator, 4 Yellow Status Indicators (Freq 0, 1, Gate 0, 1), 4 Red Wire-Off Indicators (Freq 0, 1, Gate 0, 1), 2 Yellow Status Indicators (Out 0, Out 1) - Logic Side
-
Surge Transient Immunity: Plus/Minus 2 KV line-earth(CM) On Shielded Ports
-
Surge Current: 2 A For 50 MS, Repeatable Every 2 SEC
-
Impedance: Frequency Input Impedance: Greater Than 5 KOHM For 50 MIL-V Extended Magnetic Pickup, Greater Than 5 KOHM For 500 MIL-V Magnetic Pickup, Greater Than10 KOHM For 3 V Vortex Flowmeter Low Range, Greater Than 10 KOHM For 6 V Vortex Flowmeter High Range, Greater Than 2.5 KOHM For 24 VDC IEC+1 Proximity Or Encoder Input, Greater Than 2.5 KOHM For 24 VDC Contact Switch Input, Gate Input Impedance: Greater Than 5 KOHM For 50 MIL-V Extended Magnetic Pickup, Greater Than 5 KOHM For 500 MIL-V Magnetic Pickup, Greater Than 2.5 KOHM For 24 VDC IEC+1 Proximity Or Encoder Input, Greater Than 2.5 KOHM For 24 VDC Contact Switch Input
-
Keyswitch Position: 1
-
Bus Rating: Flexbus Current: 30 MA At 5 VDC
FEATURES
-
FLEX I/O offers all the functions of larger rack-based I/O without the space requirements. Its cost effectiveness, flexibility, modularity, and reliability. FLEX I/O helps eliminate multiple long wiring runs, reduces terminations per point, decreases engineering and installation costs and time, and substantially reduces downtime. It complements all processor platforms. Can communicate on EtherNet/IP, ControlNet, DeviceNet, and PROFIBUS DP. Independently select the I/O, termination style, and network. Conformally coated, extreme environment FLEX I/O products help to reduce panel costs and the need for additional heating/cooling equipment, resulting in lower installation and maintenance costs. - Reduced space - wire direct from sensor to terminal base and eliminate terminal strip
- Functionality: 4- through 32-point modules offer functions of larger rack-based I/O
- Increased productivity: easy configuration and setup of I/O modules using wizards speeds engineering and installation
- Reduced downtime: removal and insertion under power (RIUP) and diagnostics
- Operation in harsh environments: conformal coated and extreme environment rated modules
- Network flexibility: communicates on EtherNet/IP, ControlNet, DeviceNet, and PROFIBUS DP
- Improved plant operations: HART analog modules pass through HART data to asset management software or controller for improved plant operations
- Standards: C/US UL listed, CE-ATEX, CE-EMC, CSA certified, CSA_HAZ, C-tick, GOST_R, KCC certified, marine-ABS, marine-DNV, marine-KRS, ROSTECHNADZOR, TUV-FS
- Applications: For in-cabinets
|
File description
|
File type
|
Download link
|
|
|
|
"
Spec Sheet
|
.pdf
|
Download link
|
|
|
|
|
|
|
|