Image is illustrative
|
Uninterruptible Power Supply QUINT-UPS/ 24DC/ 24DC/10/3.4AH, Phoenix Code:
2320267
Price
€516.90
/pc
(€630.62 /pc with VAT)
Manufacturer
:
Availability:
21 days
|
Weight:
4.434 kg/pc
|
Volume:
0.0089 m3/pc
|
|
|
|
|
Uninterruptible Power Supply QUINT-UPS/ 24DC/ 24DC/10/3.4AH, PhoenixDimensions
Width
|
120 mm
|
Height
|
169 mm
|
Depth
|
125 mm
|
Installation distance right/left
|
5 mm / 5 mm
|
Installation distance top/bottom
|
50 mm / 50 mm
|
Ambient conditions
Degree of protection
|
IP20
|
Ambient temperature (storage/transport)
|
-20 °C ... 40 °C
|
Max. permissible relative humidity (operation)
|
≤ 95 % (25 °C, non-condensing)
|
Climatic class
|
3K3 (in acc. with EN 60721)
|
Degree of pollution
|
2
|
Input data
Input voltage
|
24 V DC
|
Input voltage range
|
18 V DC ... 30 V DC
|
Current consumption (maximum)
|
18.6 A (24 V DC)
|
Current consumption (idle)
|
9.5 mA
|
Current consumption (charging process)
|
3.6 A
|
Output data (24 V DC mains operation)
Nominal output voltage
|
24 V DC
|
Output voltage range (depends on the input voltage)
|
18 V DC ... 30 V DC (UOUT = UIN - 0,1 V DC)
|
Nominal output current (IN)
|
10 A (0 °C ... 40 °C)
|
POWER BOOST (IBoost)
|
15 A (0 °C ... 40 °C)
|
Selective Fuse Breaking (ISFB)
|
60 A (0 °C ... 40 °C)
|
Output data (24 V DC battery operation)
Nominal output voltage
|
24 V DC
|
Output voltage range (depends on the input voltage)
|
19.2 V DC ... 27.6 V DC (UOUT = UBAT - 0,5 V DC)
|
Nominal output current (IN)
|
10 A (0 °C ... 40 °C)
|
POWER BOOST (IBoost)
|
15 A (0 °C ... 40 °C)
|
Selective Fuse Breaking (ISFB)
|
65 A (0 °C ... 40 °C)
|
General output data
Efficiency
|
> 97.6 % (Mains operation, with charged energy storage)
|
General
IQ technology
|
Yes
|
Disposal
|
Used batteries must not be thrown away with household waste, they should instead be disposed of in accordance with applicable national regulations.
|
Net weight
|
3.8 kg
|
Memory medium
|
VRLA-AGM Battery 4.0 Ah
|
Protection class
|
III
|
MTBF (IEC 61709, SN 29500)
|
> 806000 h (40 °C)
|
Mounting position
|
horizontal DIN rail NS 35, EN 60715
|
Assembly instructions
|
alignable: horizontal 5 mm, vertical 50 mm
|
Energy storage
Battery technology
|
VRLA-AGM
|
Accumulator type
|
2x BB Battery HR4.2-12FR (from UPS V/C-level 06)
|
Buffer period
|
180 min. (1 A)
|
|
10 min. (10 A)
|
Connection data, input
Connection method
|
Screw connection
|
Conductor cross section solid min.
|
0.2 mm²
|
Conductor cross section solid max.
|
2.5 mm²
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
2.5 mm²
|
Conductor cross section AWG min.
|
16
|
Conductor cross section AWG max.
|
12
|
Stripping length
|
7 mm
|
Screw thread
|
M4
|
Connection data, output
Connection method
|
Screw connection
|
Conductor cross section solid min.
|
0.2 mm²
|
Conductor cross section solid max.
|
2.5 mm²
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
2.5 mm²
|
Conductor cross section AWG min.
|
16
|
Conductor cross section AWG max.
|
12
|
Stripping length
|
7 mm
|
Screw thread
|
M4
|
Connection data for signaling
Conductor cross section solid min.
|
0.2 mm²
|
Conductor cross section solid max.
|
2.5 mm²
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
2.5 mm²
|
Conductor cross section AWG min.
|
24
|
Conductor cross section AWG max.
|
12
|
Screw thread
|
M4
|
Standards
EMC requirements for noise immunity
|
EN 61000-6-1
|
|
EN 61000-6-2
|
EMC requirements for noise emission
|
EN 61000-6-3
|
|
EN 61000-6-4
|
Standard - Electrical safety
|
EN 60950-1/VDE 0805 (SELV)
|
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
|
EN 50178/VDE 0160 (PELV)
|
Rail applications
|
EN 50121-4
|
Conformance/approvals
UL approvals
|
UL/C-UL Recognized UL 60950-1
|
|
UL Listed UL 508
|
EMC data
Electromagnetic compatibility
|
Conformance with EMC Directive 2014/30/EU
|
Low Voltage Directive
|
Conformance with Low Voltage Directive 2014/35/EC
|
Electrostatic discharge
|
EN 61000-4-2
|
Contact discharge
|
8 kV (Test Level 4)
|
Discharge in air
|
15 kV (Test Level 4)
|
Electromagnetic HF field
|
EN 61000-4-3
|
Frequency range
|
80 MHz ... 1 GHz
|
Test field strength
|
20 V/m
|
Frequency range
|
1 GHz ... 3 GHz
|
Test field strength
|
10 V/m
|
Frequency range
|
2 GHz ... 3 GHz
|
Test field strength
|
3 V/m
|
Comments
|
Criterion A
|
Fast transients (burst)
|
EN 61000-4-4
|
Input
|
2 kV (Test Level 3 - asymmetrical)
|
Output
|
2 kV (Test Level 3 - asymmetrical)
|
Signal
|
2 kV (Test Level 4 - asymmetrical)
|
Comments
|
Criterion A
|
Surge voltage load (surge)
|
EN 61000-4-5
|
Input
|
1 kV (Test Level 2 - symmetrical)
|
|
2 kV (Test Level 3 - asymmetrical)
|
Output
|
1 kV (Test Level 2 - symmetrical)
|
|
2 kV (Test Level 3 - asymmetrical)
|
Signal
|
1 kV (Test Level 2 - asymmetrical)
|
Comments
|
Criterion A
|
Conducted interference
|
EN 61000-4-6
|
I/O/S
|
asymmetrical
|
Frequency range
|
0.15 MHz ... 80 MHz
|
Voltage
|
10 V (Test Level 3)
|
Comments
|
Criterion A
|
Criterion A
|
Normal operating behavior within the specified limits.
|
Criterion B
|
Temporary impairment to operational behavior that is corrected by the device itself.
|
Environmental Product Compliance
REACh SVHC
|
Lead 7439-92-1
|
China RoHS
|
Environmentally Friendly Use Period = 3
|
|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
|
ECLASS
ECLASS 10.0.1 |
27040705
|
ECLASS 11.0 |
27040705
|
ECLASS 4.0 |
27040600
|
ECLASS 4.1 |
27040600
|
ECLASS 5.0 |
27040600
|
ECLASS 5.1 |
27040600
|
ECLASS 6.0 |
27040600
|
ECLASS 7.0 |
27040603
|
ECLASS 9.0 |
27040705
|
ETIM
ETIM 3.0 |
EC001039
|
ETIM 4.0 |
EC000382
|
ETIM 6.0 |
EC000382
|
ETIM 7.0 |
EC000382
|
UNSPSC
UNSPSC 6.01 |
30211510
|
UNSPSC 7.0901 |
39121011
|
UNSPSC 11 |
39121011
|
UNSPSC 12.01 |
39121011
|
UNSPSC 13.2 |
39121011
|
UNSPSC 18.0 |
39121011
|
UNSPSC 19.0 |
39121011
|
UNSPSC 20.0 |
39121011
|
UNSPSC 21.0 |
39121011
|
|
File description
|
File type
|
Download link
|
|
|
|
|
|
|
|
|