Image is illustrative
|
Universal Temperature Converter KFD2-UT2-Ex2, 2-ch., input TC/RTD/PM/V, signal splitter, output 0/4..20mA, sink/source, PACTware, LFD/SBD, SIL2, 24VDC PR, Pepperl+Fuchs Code:
248767
Price (indicative)
€777.00
/pc
(€947.94 /pc with VAT)
Manufacturer
:
Availability:
21 days
|
Weight:
0.153 kg/pc
|
Volume:
0.0003 m3/pc
|
|
|
|
|
Universal Temperature Converter KFD2-UT2-Ex2, 2-ch., input TC/RTD/PM/V, signal splitter, output 0/4..20mA, sink/source, PACTware, LFD/SBD, SIL2, 24VDC PR, Pepperl+FuchsUniversal Temperature Converter KFD2-UT2-Ex2
- 2-channel isolated barrier
- 24 V DC supply (Power Rail)
- Thermocouple, RTD, potentiometer or voltage input
- Usable as signal splitter (1 input and 2 outputs)
- Current output 0/4 mA ... 20 mA
- Sink or source mode
- Configurable by PACTware
- Line fault (LFD) and sensor burnout detection
- Up to SIL 2 acc. to IEC 61508/IEC 61511
Datasheet excerpt: Technical data of KFD2-UT2-Ex2
Product Description |
Current output 0/4 mA ... 20 mA |
General specifications |
Signal type | Analog input |
Functional safety related parameters |
Safety Integrity Level (SIL) | SIL 2 |
Supply |
Connection | terminals 14+, 15- or power feed module/Power Rail |
Rated voltage | 20 ... 30 V DC |
Ripple | within the supply tolerance |
Power dissipation/power consumption | ≤ 1.53 W / 1.53 W |
Interface |
Programming interface | programming socket |
Input |
Connection side | field side |
Connection | terminals 1, 2, 3; 4, 5, 6 |
RTD | type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995) type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94) type Cu10, Cu50, Cu100 (P50353-92) type Ni100 (DIN 43760) |
| Measuring current | approx. 200 µA with RTD |
| Types of measuring | 2-, 3-wire connection |
| Lead resistance | max. 50 Ω per line |
| Measurement loop monitoring | sensor breakage, sensor short-circuit |
Thermocouples | type B, E, J, K, N, R, S, T (IEC 584-1: 1995) type L (DIN 43710: 1985) type TXK, TXKH, TXA (P8.585-2001) |
| Cold junction compensation | external and internal |
| Measurement loop monitoring | sensor breakage |
Potentiometer | 0 ... 20 kΩ (2-wire connection), 0.8 ... 20 kΩ (3-wire connection) |
Voltage | selectable within the range -100 ... 100 mV |
Input resistance | ≥ 1 MΩ (-100 ... 100 mV) |
Output |
Connection side | control side |
Connection | output I: terminal 7: source (-), sink (+), terminal 8: source (+), terminal 9: sink(-) output II: terminal 10: source (-), sink (+), terminal 11: source (+), terminal 12: sink(-) |
Output I, II | Analog current output |
| Current range | 0 ... 20 mA or 4 ... 20 mA |
| Fault signal | downscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43) |
| Source | load 0 ... 550 Ω open-circuit voltage ≤ 18 V |
| Sink | Voltage across terminals 5 ... 30 V. If the current is supplied from a source > 16.5 V, series resistance of ≥ (V - 16.5)/0.0215 Ω is needed, where V is the source voltage. The maximum value of the resistance is (V - 5)/0.0215 Ω. |
Transfer characteristics |
Reaction time | worst case value (sensor breakage and/or sensor short circuit detection enabled) mV: 1.2 s, thermocouples with CJC: 1.4 s, thermocouples with fixed ref. temp: 1.4 s, 3- or 4-wire RTD: 1.1 s, 2-wire RTD: 920 ms, Potentiometer: 3-wire connection 2.8 s, 2-wire connection 2.25 s |
Indicators/settings |
Display elements | LEDs |
Configuration | via PACTware |
Labeling | space for labeling at the front |
Directive conformity |
Electromagnetic compatibility | |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity |
Electromagnetic compatibility | NE 21:2006 |
Degree of protection | IEC 60529:2001 |
Ambient conditions |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications |
Degree of protection | IP20 |
Connection | screw terminals |
Mass | approx. 130 g |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas |
EU-Type Examination Certificate | CESI 04 ATEX 143 |
| Marking | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I |
Certificate | TÜV 02 ATEX 1797 X |
| Marking | II 3G Ex nA II T4 |
Directive conformity | |
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 50303:2000 |
International approvals |
UL approval | |
| Control drawing | 116-0410 |
CSA approval | |
| Control drawing | 116-0314 (cCSAus) 116-0347 |
IECEx approval | |
| IECEx certificate | IECEx TUN 07.0003 IECEx CML 16.0126X |
| IECEx marking | [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I Ex nA IIC T4 Gc |
|
File description
|
File type
|
Download link
|
|
|
|
"
248767 datasheet
|
.pdf
|
Download link
|
|
|
|
"
Functional Safety Manual ENG
|
.pdf
|
Download link
|
|
|
|
"
Installation guide DTM Collection Interface Technology ENG
|
.pdf
|
Download link
|
|
|
|
"
Manual Isolated Barriers K-system ENG
|
.pdf
|
Download link
|
|
|
|
"
Manual KF**-UT2-(Ex)*(-1) ENG
|
.pdf
|
Download link
|
|
|
|
"
Installation et configuration de l'interface conventionnelle de collection de DTM FRA
|
.pdf
|
Download link
|
|
|
|
"
Manuel pour Barrières Isolées de Système K FRA
|
.pdf
|
Download link
|
|
|
|
"
Handbuch KF**-UT2-(Ex)*(-1) GER
|
.pdf
|
Download link
|
|
|
|
"
Handbuch Trennbarrieren K-System GER
|
.pdf
|
Download link
|
|
|
|
"
Installationsanleitung DTM Collection Interface Technology GER
|
.pdf
|
Download link
|
|
|
|
"
Manual Isolated Barriers K-system RUS
|
.pdf
|
Download link
|
|
|
|
"
Control drawing ULus / Control drawing ULus ALL
|
.pdf
|
Download link
|
|
|
|
"
Instruction manual ENG
|
.pdf
|
Download link
|
|
|
|
"
Quick Start Guide PACTware and DTM Collection Interface Technology ENG
|
.pdf
|
Download link
|
|
|
|
"
Configuration de l'interface conventionnelle de collection de DTM FRA
|
.pdf
|
Download link
|
|
|
|
"
Manuel d'instructions FRA
|
.pdf
|
Download link
|
|
|
|
"
Betriebsanleitung GER
|
.pdf
|
Download link
|
|
|
|
"
Kurzanleitung PACTware und DTM Collection Interface Technology GER
|
.pdf
|
Download link
|
|
|
|
"
Manuale di istruzioni ITA
|
.pdf
|
Download link
|
|
|
|
"
Manual de instrucciones SPA
|
.pdf
|
Download link
|
|
|
|
"
Dimension drawing 2-D (DXF) / Abmessungszeichnung 2-D (DXF)
|
.zip
|
Download link
|
|
|
|
"
Dimension drawing 3-D in IGS format / Abmessungszeichnung 3-D im IGS-Format
|
.igs
|
Download link
|
|
|
|
"
Dimension drawing 3-D in STP format / Abmessungszeichnung 3-D im STP-Format
|
.stp
|
Download link
|
|
|
|
"
ePLAN macros K-System devices (EMA) / ePLAN-Makros K-System-Geräte (EMA)
|
.zip
|
Download link
|
|
|
|
"
Australia SIMTARS Group I ANZEx 09.2001
|
.pdf
|
Download link
|
|
|
|
"
Belarus 11-1-019-2013
|
.pdf
|
Download link
|
|
|
|
"
Brasil TUV Rheinland Brazil TÜV 13.1148
|
.pdf
|
Download link
|
|
|
|
"
Canada, USA CSA CoC 1029981 USA
|
.pdf
|
Download link
|
|
|
|
"
China NEPSI GYJ 161234
|
.pdf
|
Download link
|
|
|
|
"
DNV GL Marine A-13714
|
.pdf
|
Download link
|
|
|
|
"
EAC TC RU C-DE.MH04.B.00397
|
.pdf
|
Download link
|
|
|
|
"
Europe CESI ATEX Category (1) D ATEX Category (M1) 94/9/EC (ATEX) ATEX Category (1) G CESI 04 ATEX 143
|
.pdf
|
Download link
|
|
|
|
"
Europe TUV Nord ATEX Category 3 G TÜV 02 ATEX 1797X
|
.pdf
|
Download link
|
|
|
|
"
India PESO (India) CCOE A/P/HQ/MH/104/3887 (P352047)
|
.pdf
|
Download link
|
|
|
|
"
Japan TIIS TC 21292
|
.pdf
|
Download link
|
|
|
|
"
Korea KOSHA 13-AV4BO-0176
|
.pdf
|
Download link
|
|
|
|
"
Russia Belarus EAC Kazakhstan NANIO "CCVE" TC RU C-IT.GB05.B.00718
|
.pdf
|
Download link
|
|
|
|
"
Russia VNIIMS Pattern Approval DE.C.32.004.A No.53706
|
.pdf
|
Download link
|
|
|
|
"
exida Functional Safety Assessment P+F 05/03-24 R023
|
.pdf
|
Download link
|
|
|
|
"
Control Drawing CSA / Control Drawing CSA
|
.pdf
|
Download link
|
|
|
|
"
Control Drawing CSA / Control Drawing CSA
|
.pdf
|
Download link
|
|
|
|
"
Control Drawing UL / Control Drawing UL
|
.pdf
|
Download link
|
|
|
|
|
|
|
|