Power Supply Unit QUINT4-PS/1AC/12DC/2.5/PT, 1pcs/pck, Phoenix Code:
2904605
Price
€69.50
/pc
(€84.79 /pc with VAT)
Manufacturer
:
Availability:
28 days
|
Weight:
0.238 kg/pc
|
|
|
|
|
|
Power Supply Unit QUINT4-PS/1AC/12DC/2.5/PT, 1pcs/pck, PhoenixDimensions
Width
|
22.5 mm
|
Height
|
106 mm
|
Depth
|
90 mm
|
Installation distance right/left (active, passive)
|
0 mm / 0 mm (POut ≤50 %)
|
Installation distance right/left (passive)
|
5 mm / 5 mm (POut ≥50% )
|
Installation distance right/left (active)
|
15 mm / 15 mm (POut ≥50% )
|
Installation distance top/bottom (active, passive)
|
30 mm / 30 mm (POut ≤50 %)
|
Installation distance top/bottom (passive)
|
30 mm / 30 mm (POut ≥50% )
|
Installation distance top/bottom (active)
|
30 mm / 30 mm (POut ≥50% )
|
Ambient conditions
Degree of protection
|
IP20
|
Inflammability class in acc. with UL 94 (housing / terminal blocks)
|
V0
|
Ambient temperature (operation)
|
-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
|
Ambient temperature (storage/transport)
|
-40 °C ... 85 °C
|
Max. permissible relative humidity (operation)
|
≤ 95 % (at 25 °C, non-condensing)
|
Climatic class
|
3K3 (in acc. with EN 60721)
|
Degree of pollution
|
2
|
Installation height
|
≤ 5000 m (> 2000 m, observe derating)
|
Input data
Input voltage range
|
100 V AC ... 240 V AC -15 % ... +10 %
|
|
110 V DC ... 250 V DC -20 % ... +40 %
|
Dielectric strength maximum
|
300 V AC 60 s
|
Frequency range (fN)
|
50 Hz ... 60 Hz -10 % ... +10 %
|
Discharge current to PE
|
< 0.25 mA (264 V AC, 60 Hz)
|
Current consumption
|
0.44 A (100 V AC)
|
|
0.35 A (120 V AC)
|
|
0.19 A (230 V AC)
|
|
0.2 A (240 V AC)
|
Nominal power consumption
|
32.8 VA
|
Inrush current
|
typ. 11.3 A (at 25 °C)
|
Mains buffering time
|
typ. 54 ms (120 V AC)
|
|
typ. 54 ms (230 V AC)
|
Input fuse
|
3.15 A (slow-blow, internal)
|
Recommended breaker for input protection
|
6 A ... 16 A (Characteristic B, C or comparable)
|
Type of protection
|
Transient surge protection
|
Protective circuit/component
|
Varistor
|
Output data
Nominal output voltage
|
12 V DC
|
Setting range of the output voltage (USet)
|
12 V DC ... 15 V DC (constant capacity)
|
Nominal output current (IN)
|
2.5 A
|
Static Boost (IStat.Boost)
|
3.125 A (≤ 40 °C)
|
Dynamic Boost (IDyn.Boost)
|
4.5 A (≤ 60 °C (5 s))
|
Connection in parallel
|
yes, for redundancy and increased capacity
|
Connection in series
|
yes
|
Feedback voltage resistance
|
≤ 25 V DC
|
Protection against overvoltage at the output (OVP)
|
≤ 18 V DC
|
Control deviation
|
< 0.2 % (Static load change 10 % ... 90 %)
|
|
< 2 % (Dynamic load change 10 % ... 90 %, (10 Hz))
|
|
< 0.1 % (change in input voltage ±10 %)
|
Residual ripple
|
< 30 mVPP (with nominal values)
|
Output power
|
30 W
|
Typical response time
|
500 ms
|
Maximum power dissipation in no-load condition
|
< 0.4 W (230 V AC)
|
|
< 0.5 W (120 V AC)
|
Power loss nominal load max.
|
< 3.5 W (120 V AC)
|
|
< 3 W (230 V AC)
|
General
Net weight
|
0.181 kg
|
Efficiency
|
typ. 89.5 % (120 V AC)
|
|
typ. 90.9 % (230 V AC)
|
MTBF (IEC 61709, SN 29500)
|
> 1848000 h (25 °C)
|
|
> 1060000 h (40 °C)
|
|
> 459000 h (60 °C)
|
Insulation voltage input/output
|
4 kV AC (type test)
|
|
3 kV AC (routine test)
|
Degree of protection
|
IP20
|
Protection class
|
II
|
Inflammability class in acc. with UL 94 (housing / terminal blocks)
|
V0
|
Connection data, input
Connection method
|
Push-in connection
|
Conductor cross section solid min.
|
0.2 mm²
|
Conductor cross section solid max.
|
2.5 mm²
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
2.5 mm²
|
Conductor cross section AWG min.
|
24
|
Conductor cross section AWG max.
|
14
|
Stripping length
|
10 mm
|
Connection data, output
Connection method
|
Push-in connection
|
Conductor cross section solid min.
|
0.2 mm²
|
Conductor cross section solid max.
|
2.5 mm²
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
2.5 mm²
|
Conductor cross section AWG min.
|
24
|
Conductor cross section AWG max.
|
14
|
Stripping length
|
10 mm
|
Connection data for signaling
Connection method
|
Push-in connection
|
Conductor cross section solid min.
|
0.2 mm²
|
Conductor cross section solid max.
|
2.5 mm²
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
2.5 mm²
|
Conductor cross section AWG min.
|
24
|
Conductor cross section AWG max.
|
14
|
Stripping length
|
10 mm
|
Standards
EMC requirements, power plant
|
IEC 61850-3
|
|
EN 61000-6-5
|
Standard - Safety of transformers
|
EN 61558-2-16
|
Standard - safety for equipment for measurement, control, and laboratory use
|
IEC 61010-1
|
Standard – Safety extra-low voltage
|
IEC 61010-1 (SELV)
|
|
IEC 61010-2-201 (PELV)
|
Standard - Safe isolation
|
IEC 61558-2-16
|
Standard – Limitation of mains harmonic currents
|
EN 61000-3-2
|
Overvoltage category EN 61010-1
|
II (≤ 5000 m)
|
Overvoltage category EN 62477-1
|
III (≤ 2000 m)
|
Conformance/approvals
UL approvals
|
UL Listed UL 61010-1
|
|
UL Listed UL 61010-2-201
|
|
UL 1310 Class 2 Power Units
|
|
ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
|
SIQ
|
CB-Scheme (IEC 61010-1, IEC 61010-2-201)
|
EMC data
Electromagnetic compatibility
|
Conformance with EMC Directive 2014/30/EU
|
Conducted noise emission
|
EN 55016
|
|
EN 61000-6-3 (Class B)
|
Noise emission
|
EN 55016
|
|
EN 61000-6-3 (Class B)
|
Harmonic currents
|
EN 61000-3-2
|
|
EN 61000-3-2 (Class A)
|
Flicker
|
EN 61000-3-3
|
Electrostatic discharge
|
EN 61000-4-2
|
Contact discharge
|
8 kV (Test Level 4)
|
Discharge in air
|
15 kV (Test Level 4)
|
Electromagnetic HF field
|
EN 61000-4-3
|
Frequency range
|
80 MHz ... 1 GHz
|
Test field strength
|
20 V/m (Test Level X)
|
Frequency range
|
1 GHz ... 6 GHz
|
Test field strength
|
10 V/m (Test Level 3)
|
Comments
|
Criterion A
|
Fast transients (burst)
|
EN 61000-4-4
|
Input
|
4 kV (Test Level 4 - asymmetrical)
|
Output
|
4 kV (Test Level X - asymmetrical)
|
Signal
|
4 kV (Test Level X - asymmetrical)
|
Comments
|
Criterion A
|
Surge voltage load (surge)
|
EN 61000-4-5
|
Input
|
2 kV (Test Level 4 - symmetrical)
|
|
4 kV (Test Level 4 - asymmetrical)
|
Output
|
1 kV (Test Level 3 - symmetrical)
|
|
2 kV (Test Level 3 - asymmetrical)
|
Signal
|
0.5 kV (Test Level 2 - symmetrical)
|
Comments
|
Criterion A
|
Conducted interference
|
EN 61000-4-6
|
I/O/S
|
asymmetrical
|
Frequency range
|
0.15 MHz ... 80 MHz
|
Voltage
|
10 V (Test Level 3)
|
Comments
|
Criterion A
|
Power frequency magnetic field
|
EN 61000-4-8
|
Frequency
|
16.67 Hz
|
|
50 Hz
|
|
60 Hz
|
Test field strength
|
100 A/m
|
Additional text
|
60 s
|
Comments
|
Criterion A
|
Frequency
|
50 Hz
|
|
60 Hz
|
Frequency range
|
50 Hz ... 60 Hz
|
Test field strength
|
1 kA/m
|
Additional text
|
3 s
|
Frequency
|
0 Hz
|
Test field strength
|
300 A/m
|
Additional text
|
DC, 60 s
|
Voltage dips
|
EN 61000-4-11
|
Voltage
|
100 V AC
|
Frequency
|
60 Hz
|
Voltage dip
|
70 %
|
Number of periods
|
0.5 / 1 / 30 periods
|
Additional text
|
Test Level 2
|
Comments
|
Criterion A
|
Voltage dip
|
40 %
|
Number of periods
|
5 / 10 / 50 periods
|
Additional text
|
Test Level 2
|
Comments
|
Criterion B
|
Voltage dip
|
0 %
|
Number of periods
|
0.5 / 1 / 5 / 50 periods
|
Additional text
|
Test Level 2
|
Comments
|
Criterion B
|
Pulse-shape magnetic field
|
EN 61000-4-9
|
Test field strength
|
1000 A/m
|
Comments
|
Criterion A
|
Attenuated sinusoidal oscillations (ring wave)
|
EN 61000-4-12
|
Input
|
2 kV (symmetrical)
|
|
4 kV (asymmetrical)
|
Comments
|
Criterion A
|
Asymmetrical conducted disturbance variables
|
EN 61000-4-16
|
Test level 1
|
16.67 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
|
Voltage
|
30 V (10 s)
|
Test level 2
|
16.67 Hz 50 Hz 60 Hz (Test Level 2)
|
Voltage
|
300 V (1 s)
|
Comments
|
Criterion A
|
Attenuated oscillating wave
|
EN 61000-4-18
|
Voltage
|
1 kV (symmetrical)
|
|
2.5 kV (asymmetrical)
|
|
1 kV (symmetrical)
|
Comments
|
Criterion A
|
Criterion A
|
Normal operating behavior within the specified limits.
|
Criterion B
|
Temporary impairment to operational behavior that is corrected by the device itself.
|
Criterion C
|
Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
|
ECLASS
ECLASS 10.0.1 |
27040701
|
ECLASS 11.0 |
27040701
|
ECLASS 5.1 |
27242213
|
ECLASS 6.0 |
27049000
|
ECLASS 7.0 |
27049002
|
ECLASS 9.0 |
27040701
|
ETIM
ETIM 6.0 |
EC002540
|
ETIM 7.0 |
EC002540
|
UNSPSC
UNSPSC 13.2 |
39121004
|
UNSPSC 18.0 |
39121004
|
UNSPSC 19.0 |
39121004
|
UNSPSC 20.0 |
39121004
|
UNSPSC 21.0 |
39121004
|
|
File description
|