Image is illustrative
|
ModMus Master/Slave Interface Module, debug/config. EtherNet port (E1), 3mA 24VDC backplane Code:
MVI56E-MCM
Price (indicative)
€3,343.84
/pc
(€4,079.48 /pc with VAT)
Manufacturer
:
Availability:
21 days
|
Weight:
1.36 kg/pc
|
Volume:
0.0046 m3/pc
|
|
|
|
|
Modbus Master/Slave Interface Module, debug/configuration Ethernet port (E1), 3mA 24VDC backplane, Prosoft Technology
Modbus Master/Slave Interface Module, Communication Speed: 110 Baud - 115.2 KBPS, Communication Protocol: Modbus, Interface: Debug/Configuration Ethernet Port (E1), Serial Application Ports (P1 And P2), Power Supply: 800 MA At 5 VDC, 3 MA At 24 VDC Backplane Current Load, Functions: Command Control, Event Commands, Status, Memory: 10000 16-Bit Registers, Temperature Rating: 0 - 60 DEG C, Consist Of: RJ45 To DB-9M Cables For Each Serial Port, 5 FT Ethernet Straight-Thru Gray Cable, Indicator: LED Indicator: Battery Status (ERR), Application Status (APP), Module Status (OK), Application: For Modbus master and/or slave connectivity from Rockwell Automation® ControlLogix® processors to Modbus RTU/ASCII devices
|
|
Specifications
- Item Name: Modbus Master/Slave Interface Module
- Communication Speed: 110 Baud - 115.2 KBPS
- Communication Protocol: Modbus
- Interface: Debug/Configuration Ethernet Port (E1), Serial Application Ports (P1 And P2)
- Power Supply: 800 MA At 5 VDC, 3 MA At 24 VDC Backplane Current Load
- Functions: Command Control, Event Commands, Status
- Memory: 10000 16-Bit Registers
- Temperature Rating: 0 - 60 DEG C
- Consist Of: RJ45 To DB-9M Cables For Each Serial Port, 5 FT Ethernet Straight-Thru Gray Cable
- Indicator: LED Indicator: Battery Status (ERR), Application Status (APP), Module Status (OK)
Features
The MVI56E-MCM act as input/output modules on the ControlLogix backplane, making Modbus data appear as I/O data to the processor. Two independently configurable serial ports can operate on the same or different Modbus networks. The MVI56E-MCM is designed for standard process applications and the MVI56E-MCMXT is designed for the Logix-XT control platform, allowing it to operate in extreme environments. Can tolerate higher operating temps, and has conformal coating for protection in harsh or caustic conditions
All MVI56E products are backward-compatible with earlier MVI56 modules allowing direct replacement without the need to change existing controller programs
Allows you to gather more data from your devices, which improves operational performance
inserted module
Module configuration stored within the RSLogix™ 5000 project (ACD file)
No additional programming or configuration software is required
Add-On Instruction for RSLogix 5000 version 16 or higher cuts development time and costs
Facilitates remote user access across the ControlLogix backplane through Rockwell Automation’s 1756-ENBT module
Configure, diagnose, and analyze process data and communications status
Bridge through multiple ENBT/CNBT links to connect to MVI56E-MCMs installed in remote chassis for configuration and diagnostics
Simplifies adding the module in an RSLogix 5000 project
10/100 MB Ethernet port for network configuration and diagnostics with auto cable crossover detection
User-definable module data memory mapping of up to 10,000 16-bit registers
4-character, scrolling, alphanumeric LED display of status and diagnostic data in plain English
ProSoft Discovery Service (PDS) software finds the module on the network and assigns a temporary IP address to facilitate module access
Supports RIUP (Remove and Insert Under Power)
Supports Enron version of Modbus protocol for floating-point data transactions
PCB includes powerful Modbus network analyzer
Error codes, network error counters, and port status data available in user data memory
Special functions (command control, event commands, status, and so on) are supported by message transfer (unscheduled) using the MSG instruction
Applications: For Modbus master and/or slave connectivity from Rockwell Automation® ControlLogix® processors to Modbus RTU/ASCII devices
|
|
|
|
|