Digital Panel Meter N30U, input RTD/ TC/ V/ I, output 0/4..20mA/0..10V/ RS485/ 4CO, LED display, progr. PD20, LPConfig, sv 20..40VAC/ 20..60VDC, □92x45mm, IP65
Image is illustrative
Digital Panel Meter N30U, input RTD/ TC/ V/ I, output 0/4..20mA/0..10V/ RS485/ 4CO, LED display, progr. PD20, LPConfig, sv 20..40VAC/ 20..60VDC, □92x45mm, IP65
Code: N30U-220000E0
Price
€298.00  /pc
(€369.52 /pc with VAT)
Manufacturer :
Availability:
21 days
Weight:
0.378 kg/pc
Volume:
0.0012 m3/pc
Quantity (pc):
Plus sign Minus sign
 

Overview
Digital panel meter for measuring temperature, resistance, voltage, current, standard analogue signals, with a two-line backlit LCD display, programmable measurement functions, alarm outputs, analogue output, auxiliary supply, RS-485 Modbus RTU communication.
Display
Display type High-contrast two-line LCD with backlight
Upper row 6 digits, 12.85mm digit height
Lower row 5 digits, 7.5mm digit height
Measurement unit Programmable
Measurement Inputs
Resistance sensors Pt100, Pt1000
Resistance ranges 0..440Ω, 0..4040Ω
Thermocouples J, K, N, E, R, S
Voltage input -13..13V
Current input -24..24mA
Standard current input 3.6..22mA
Shunt inputs 60mV, 150mV, 300mV
Accuracy class 0.1
Measurement Functions
Individual characteristic 32 points
Mathematical functions √x, x², 1/x, (1/x)², √(1/x)
Value memory Minimum, maximum
Averaging Programmable walking-window algorithm
Programming Front keyboard, RS-485 interface
Outputs
Alarm outputs 1 or 4 relay outputs
Relay contact rating 5A 250VAC/ 30VDC or 6A 250VAC/ 30VDC
Analogue current output 0/4..20mA
Analogue voltage output 0..10V
Binary output Passive NPN, 30VDC/ 30mA
Auxiliary supply 24VDC/ 30mA
Communication
Interface RS-485
Protocol Modbus RTU
Transmission mode 8N2, 8E1, 8O1, 8N1
Baud rate 2.4..115.2kbit/s
Power Supply
Standard supply 85..253VAC, 90..300VDC
Low-voltage supply 20..40VAC, 20..60VDC
Power consumption <6VA
Mechanical Data
Overall dimensions 96x48x93mm
Panel cut-out 92x45mm
Operating position Any
Environmental Conditions
Ambient temperature -25..55°C
Storage temperature -30..70°C
Relative humidity 25..95%, without condensation
Operating altitude <2000m
Protection ^Safety
Front protection IP65
Terminal protection IP10
Pollution level 2
Installation category III
Safety standard EN 61010-1
Related products
 
Converter PD20, isolated USB » RS485 interface, USB 2.0 type A, ModBus RTU/ACSII  
€73.60 /pc

21 days
 
 
 
Elit OÜ | e-post: elit@elit.ee | +372 622 9119 | 2016 ©


 
X
 
X