Image is illustrative
|
DC Current Transducer P20H, input ±5ADC, output 4..10V, progr. PD14-0 ^eCon, sv 20..40VAC 40..400Hz/ 20..60VDC Code:
P20H-53200E0
Price
€275.00
/pc
(€341.00 /pc with VAT)
Manufacturer
:
|
Availability:
21 days
|
Weight:
0.189 kg/pc
|
Volume:
0.0008 m3/pc
|
|
|
|
|
Overview
Programmable transducer for continuous conversion of high DC current or high DC voltage signals into standard analog output signals or digital data through an RS-485 interface.
Features
|
Conversion
|
Continuous DC current or DC voltage signal conversion
|
|
Accuracy class
|
0.2
|
|
Configuration
|
PD14 programmer with LPCon software
|
|
Programmable parameters
|
Measurement averaging time, conversion characteristic, output signal at overflow, output signal narrowing, RS-485 parameters
|
|
Galvanic isolation
|
Supply, measuring input, output
|
Inputs
|
Unipolar DC voltage
|
0..100VDC, 0..250VDC, 0..400VDC
|
|
Bipolar DC voltage
|
±100VDC, ±250VDC, ±400VDC
|
|
Bipolar DC current
|
±1ADC, ±5ADC
|
|
Voltage input resistance
|
>2MΩ
|
|
1A input resistance
|
10mΩ ±10%
|
|
5A input resistance
|
2mΩ ±10%
|
|
Basic error
|
±0.2% of range
|
|
Short-duration overload
|
2xUn below 1000V, 10xIn for 1s
|
Outputs
|
Current output
|
0..20mA or 4..20mA
|
|
Current output load
|
≤500Ω
|
|
Voltage output
|
0..10VDC
|
|
Voltage output load
|
≥500Ω
|
|
Resolution
|
0.01% of range
|
Digital Interface
|
Interface
|
RS-485
|
|
Protocol
|
MODBUS RTU
|
|
Transmission modes
|
8N2, 8E1, 8O1, 8N1
|
|
Baud rates
|
4.8kbit/s, 9.6kbit/s, 19.2kbit/s
|
Power Supply
|
Supply option 1
|
85..253VAC 40..400Hz or 90..300VDC
|
|
Supply option 2
|
20..40VAC 40..400Hz or 20..60VDC
|
|
Power consumption
|
<3VA
|
Operating Conditions
|
Ambient temperature
|
-20..60°C
|
|
Storage temperature
|
-25..85°C
|
|
Relative humidity
|
<95%, non-condensing
|
|
Operating position
|
Any
|
|
Preheating time
|
15min
|
|
Measurement averaging time
|
≥0.1s
|
Galvanic Isolation
|
Supply to measuring input
|
3.2kVDC
|
|
Supply to output
|
2kVDC
|
|
Measuring input to output
|
3.2kVDC
|
Safety ^Compatibility
|
Safety standard
|
EN 61010-1
|
|
Noise immunity
|
EN 61000-6-2
|
|
Noise emissions
|
EN 61000-6-4
|
|
Pollution grade
|
2
|
|
Installation category
|
III, category II for 400V input
|
|
Operating altitude
|
<2000m
|
External Features
|
Dimensions
|
22.5x120x100mm
|
|
Housing protection
|
IP40
|
|
Terminal protection
|
IP20
|
|
Mounting
|
35mm rail according to EN 60715
|
|
|
|
Related products
|
|
|
|
Programmer, USB » RJ11, progr. P11, P12, P20, N24 transducers, digital meters, network parameter meters, transducers, controllers, others (eCon)
|
|
|
€58.70 /pc
|
|
|
|